Installation to a Solid Wall
1. Determine the route for the hot and cold supply pipework.
2. Determine the desired position of the mixer valve.
Note! To enable sufficient clearance the valve must be a
minimum 1.1 m from the ceiling.
3. Cut away the brick work to the required depth.
4. Install the supply pipework using the Pipe Spacer to secure as
necessary, the pipework should extend a minimum of 50 mm
from the nished wall surface. Use the Tiling Guide to ensure the
pipe centres are correct (50 mm) Note! Ensure that the pipework
protruding from the wall is level and rigidly secured. Plastic piping
must not be used to connect the valve to the supply pipework.
5. Finish the wall e.g. Tiles, making sure to tile around the tile guide.
6. Follow steps 9 - 17 from section “Installation to a Panelled /
Partition Wall” .
7. Turn on the water supplies and check for leaks.
8. The installation of the mixer valve to a solid wall is now complete.
FITTINGS
Please refer to the Fittings Installation and User Guide.
COMMISSIONING
Before using the shower the maximum temperature must be
checked to make sure that it is at a safe level. It has been preset
to approximately 41°C at the factory but due to variations in site
conditions the maximum temperature may need adjustment.
Note! Make sure that the hot water temperature is at least 55°C and
that there is sufcient supply.
Turn on the mixer to the maximum temperature and maximum ow
and allow the temperature to stabilise. If the temperature is too hot
or too cold adjust as follows:
• Agile Single Control models - Pull the control from the
body then unscrew the hub retaining screw with a 2.5 mm
hexagonal key. Note! Do not remove the hub.
• Agile Dual Control models - Carefully remove the
concealing cap from the control.
1. Insert the 2.5 mm hexagonal key into the centre of the spindle
and engage with the recessed temperature adjusting screw.
2. Rotate the hexagonal key until the required maximum
temperature is obtained at the shower. Anticlockwise to increase
the temperature, or clockwise to decrease the temperature (¼
turn = approximately 1°C).
3. Once the desired maximum blend temperature has been
achieved turn off the mixer by rotating either the hub or ow
control (depending on model) fully clockwise. Note! Do not
remove the hub.
4. Ret the hub retaining screw then ret the control (Agile Single
Control model).
5. Ret the concealing cap (Agile Dual Control).
6. Check that the shower temperature is correct.
Ensure that the
pipework is level
OPERATION
Mira Agile Dual Control thermostatic mixers have separate controls
for on/off and temperature.
The controls operate in the following sequence:
Flow Control (anti-clockwise)
Off
Reduced Flow Overide *
Full Flow
Temperature Control
Temp Control (anti-clockwise)
Full Hot
41°
Full Cold
Flow Control
* Reduced Flow Overide - reduces water ow by up to 30%
(dependant on inlet pressures) and can be overidden by increasing
ow to full.
USER MAINTENANCE
Filter Replacement
1. Isolate the water supplies.
2. Open the ow control to relieve water pressure and to drain
any residual water.
3. Unscrew the shower hose or rigid riser from the mixer outlet.
4. Remove mixer valve in reverse order of install. See section
“INSTALLATION”
5. Pull the mixer from the wall.
6. The lters are retained in the mixer valve, remove and inspect for
debris blockage. Clean the lters under a jet of water to remove
any lodged particles.
7. Ret or replace the lters and reassemble in reverse order.
8. Restore the water supplies and check for leaks.
Lubricants
Silicone based lubricants must only be used on the rubber seals.
Caution! Oil based or other lubricant types may cause rapid
deterioration of seals.
Cleaning
The chrome plated parts should be cleaned using a mild washing up
detergent or soap solution, rinsed and then wiped dry with a soft cloth.
Warning! Many household cleaners contain abrasive and chemical
substances, and should not be used for cleaning plated or plastic
ttings.
Do not use descalents on this product.
FAULT DIAGNOSIS
Symptom:
• Onlyhotorcoldwaterfromthemixeroutlet.
• Outlettemperaturetoohot/toocold.
CauseRectication:
• Inletsreversed(hotsupplytocoldsupply).Installationerror,
supplypipeworkrequiresrework.
• Nohotwaterreachingmixer.
• Check the filters for any blockage refer to section USER
MAINTENANCE’.
• Installation conditions outside operating parameters, refer to
sections:‘SPECIFICATIONand‘COMMISSIONING’.
• Ifthetemperatureistoocoldandyouhaveacombinationtype
boileritmaynotbeproducingsufcientlyhotwateratdesiredow
rate(refertoSPECIFICATION’).Makesureowregulatoristted.
FormoreinformationcontactMiraShowersorvisitthewebsite..
—————————————
Symptom:
• Fluctuatingorreducedowrate.
CauseRectication:
• Checktheshowerhead,hoseandltersforanyblockage.
• Make sure that the maintained inlet pressures are nominally
balancedandsufcient,refertosection:‘SPECIFICATION’.
• Makesurethattheinlettemperaturedifferentialsaresufcient,
refertosection:‘SPECIFICATION’.
• Airlockorpartialblockageinthepipework.
• Low ow causing combination boiler to cycle. Operate shower
atfullow.
• Remove12L/minowregulatorifusedwithagravityfedsystem,
seeFittingsInstallationandUserGuide.
—————————————
Symptom:
• Waterleakingfromtheshowerhead.
CauseRectication:
• Normalforashortperiodaftershutoff.
• Checkthatthepressuresarenotinexcessofthespecications
fortheproduct.
• Renewthecartridge.
SPARE PARTS
1736.707 Screw Pack - Components Identied A’
1736.708 Seal Pack - Components Identied ‘B’
1736.717 Component Pack - Components Identied ‘C’
1199918-W2-A (1736)
© Kohler Mira Limited, October 2012
What to do if something goes wrong
If your product does not work correctly refer to this manual for fault diagnosis
and check that it is installed and commissioned in accordance with our
instructions.
If this does not resolve the issue, contact us for help and advice.
Extended Guarantees
A selection of protection plans are available that enable you to cover
repair bills (excludes Eire). Ring 01922 471763 for more details.
Helpdesk Service - Ring our Customer Services Team for
product advice, to purchase spare parts or accessories or to
set up service visit. You can contact us via phone or e-mail,
details below. Please provide your model name, power rating (if
applicable) and date of purchase.
Mira Showers Website (www.mirashowers.co.uk)
Visit our website to register your guarantee, download user
guides, diagnose faults, purchase our full range of accessories
and popular spares, or request a service visit.
Spares and Accessories - We hold the largest stocks of genuine
Mira spares and accessories. Contact us for a price or visit our
website to purchase items from our accessory range and popular
spares.
Service/Repairs - No one knows our products better than our
nationwide team of Service Technicians. We can carry out service
or repair work to your product both during and after the guarantee
period. Ask about our xed price service repairs.
01 459 1344
Mira Customer Services
Dept, Cromwell
Road, Cheltenham,
Gloucestershire, GL52 5EP
To Contact Us
Fax: Dublin 01 459 2329
E-mail: Visit www.
mirashowers.co.uk/
contactus
To Contact Us: Eire Only
Modern Plant Ltd (Dublin),
Otter House, Naas Road,
Clondalkin, Dublin 22
0844 571 5000
Fax: 01 242 282595
The guarantee does not cover:
Call out charges for non product faults (such as damage or performance
issues arising from incorrect installation, improper use, inappropriate
cleaning, lack of maintenance, build up of limescale, frost damage,
corrosion, system debris or blocked lters) or where no fault has been
found with the product.
Water or electrical supply, waste and isolation issues.
Compensation for loss of use of the product or consequential loss of
any kind.
Damage or defects caused if the product is repaired or modied by
persons not authorised by us or our appointed representative.
Routine maintenance or replacement parts to comply with the
requirements of the TMV 2 or TMV 3 healthcare schemes.
Accidental or wilful damage.
Products purchased ex-showroom display.
Mira is a registered trade mark of
Kohler Mira Limited.
The company reserves the right to alter
product specications without notice.
FM 14648
CUSTOMER SERVICE
Guarantee
Your product has the benet of our manufacturer’s guarantee which starts
from the date of purchase. To activate this guarantee, please return your
completed registration card, visit our website or free phone 0800 0731248
within 30 days of purchase (UK only).
Within the guarantee period we will resolve defects in materials or
workmanship, free of charge, by repairing or replacing parts or product as
we may choose.
This guarantee is in addition to your statutory rights and is subject to
the following conditions:
The guarantee applies solely to the original installation under normal use
and to the original purchaser only. The product must be installed and
maintained in accordance with the instructions given in this user guide.
Servicing must only be undertaken by us or our appointed representative.
Note! If a service visit is required the product must be fully installed and
connected to services.
Repair under this guarantee does not extend the original expiry date.
The guarantee on any replacement parts or product ends at the original
expiry date.
For shower ttings or consumable items we reserve the right to supply
replacement parts only.
Mira Agile
Thermostatic Mixer
These instructions must be left with the user
Installation
and User Guide
For SPARES, ADVICE
or REPAIRS
Please call us on
0844 571 5000
(UK Only)
Having completed the installation, make sure the user is familiar with
the operation of the shower.
Mira Agile Single Control uses a single sequential control for
on/off and temperature control.
The control operates anti-clockwise in the following sequence:
Off
Cold
Hot (Maximum Preset Temperature)
2.5 mm Hexagonal
Key
Control
Hub Retaining
Screw
Mira Agile Single Control
2.5 mm
Hexagonal Key
Flow Control
Temperature
Control
Mira Agile Dual Control
Concealing
Cap
Dual Control Valve
1678.339
Filters
1736.709
Backplate
1678.340
Collets
C
C
B
B
A
B
1736.704
Cartridge
1736.705
Control
Assembly
1736.706
Outlet
Plug
A
1736.703
Cartridge
1736.702
Concealing
Cap
1736.700
Flow
Control
1736.701
Temperature
Control
A
Single Control Valve
Page view 0
1 2

Summary of Contents

Page 1 - Thermostatic Mixer

Installation to a Solid Wall1. Determine the route for the hot and cold supply pipework. 2. Determine the desired position of the mixer valve. No

Page 2 - Use pipe slice

Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly, havi

Comments to this Manuals

No comments