1These instructions must be left with the userInstallation GuideMira Sport7.5, 9.0, 9.8 & 10.8 kW
10INSTALLATIONCoverCaution! Do not drill into buried cables or pipes.Warning! Isolate the electrical and water supplies before installing the shower.S
11Rotate the inlet connector to suit the direction of the incoming water supply.Case InsertCase InsertInlet ConnectorSecure the shower to the wall.
12LNLoosen the screws in the terminal block and insert the wires.Inlet ConnectorOliveCompression NutInlet Supply PipeConnect the inlet supply pipe to
13Ensure the earth bonding complies with relevant regulations.Replace the service tunnel.Ensure the control dials are aligned with the spindles and re
14COMMISSIONINGSwitch on the electrical supply.Turn temperature control to the cold position.Turn power control to low.button. Light i
15Turn power control to High. Temperature will rise further.Turn power control to Eco. Temperature will rise slightly.
16FAULT DIAGNOSISIn the event of a malfunction of the shower, the troubleshooting information below
17SymptomStart/Stop Light is ON or OFFPower Control PositionPossible Cause Possible RemedyShowerhead dripping.OFF pressure
18SymptomStart/Stop Light is ON or OFFPower Control PositionPossible Cause Possible RemedyNo change in temperature between Low / Eco /High setting.ON
19Inlet Connector Inlet FilterSERVICINGScrewsService TunnelScrewCoverWARNINGThere are no user serviceable parts inside the shower.
2refer to “Fault Diagnosis”, before contacting Kohler Mira Limit
20SPARE PARTS1746.448Service Tunnel406.27Inlet Filter1746.434Inlet Connector1746.435Inlet Clamp1746.437Coil1746.446Switch / LED 1746.445Cover1
21ACCESSORIESGenuine Mira accessories can be purchased direct from Customers Services (our contact details can
22NOTES
23NOTES
24CUSTOMER SERVICE1175283-W2-B © Kohler Mira Limited, November 2011Mira is a registered trade mark of Kohler Mira Limited.
1These instructions must be left with the userLOW HIGHECOTEMPERATUREPOWERUser Guide
2to section 'FAULT DIAGNOSIS'
3IMPORTANT SAFETY INFORMATION Make sure that you fully understand how
4OPERATION“IMPORTANT SAFETY INFORMATION”Switch on the electrical LOW HIGHECOPOWERTurn power control to the
5
3IMPORTANT SAFETY INFORMATIONWARNING - This shower can deliver scalding temperatures if not operated, installed or maintained in accordance with the i
6USER MAINTENANCEUse your thumb or a soft cloth to wipe any limescale from the soft nozzlesThere are no user serviceable parts
7SymptomStart/Stop Light is ON or OFFPowerControl PositionPossible Cause Possible RemedyShower fails OFF Isolator switch in the off
8CUSTOMER SERVICEMira is a registered trade mark of Kohler Mira Limited.
4PACK CONTENTSDocumentationTick the appropriate boxes to familiarise yourself with the part names and to 1 x Mira
5WIRING DIAGRAMINLET CONNECTORTERMINAL BLOCKHEATER TANKMICROSWITCH (L)MICROSWITCH (R)SOLENOIDLED/LED HOUSINGPUSH BUTTON SWITCHBROWN BGREEN DBLUE CRED
6SPECIFICATIONSEuropean Conformity InformationThe Mira Sport range of showers complies with the following European directives:2006/95/EC Low Voltage D
7INSTALLATION REQUIREMENTSthe front of this guide, and the requirements det
8Zone of 30 mm MinimumToilet or Bid
9LOW HIGHECOPOWERTEMPERATUREWARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:Electrical1. The electrical installation must comply with
Comments to this Manuals