1These instructions must be left with the userInstallation GuideMira Sport7.5, 9.0, 9.8 & 10.8 kW

Page 2 - INTRODUCTION

10INSTALLATIONCoverCaution! Do not drill into buried cables or pipes.Warning! Isolate the electrical and water supplies before installing the shower.S

Page 3

11Rotate the inlet connector to suit the direction of the incoming water supply.Case InsertCase InsertInlet ConnectorSecure the shower to the wall. 

Page 4 - PACK CONTENTS

12LNLoosen the screws in the terminal block and insert the wires.Inlet ConnectorOliveCompression NutInlet Supply PipeConnect the inlet supply pipe to

Page 5 - WIRING DIAGRAM

13Ensure the earth bonding complies with relevant regulations.Replace the service tunnel.Ensure the control dials are aligned with the spindles and re

Page 6 - SPECIFICATIONS

14COMMISSIONINGSwitch on the electrical supply.Turn temperature control to the cold position.Turn power control to low.button. Light i

Page 7 - INSTALLATION REQUIREMENTS

15Turn power control to High. Temperature will rise further.Turn power control to Eco. Temperature will rise slightly.   

Page 8 - 

16FAULT DIAGNOSISIn the event of a malfunction of the shower, the troubleshooting information below 

Page 9

17SymptomStart/Stop Light is ON or OFFPower Control PositionPossible Cause Possible RemedyShowerhead dripping.OFF pressure

Page 10 - INSTALLATION

18SymptomStart/Stop Light is ON or OFFPower Control PositionPossible Cause Possible RemedyNo change in temperature between Low / Eco /High setting.ON

Page 11

19Inlet Connector Inlet FilterSERVICINGScrewsService TunnelScrewCoverWARNINGThere are no user serviceable parts inside the shower. 

Page 12 - Green /Yellow sleeved wire

2refer to “Fault Diagnosis”, before contacting Kohler Mira Limit

Page 13 - TEMPERATURE

20SPARE PARTS1746.448Service Tunnel406.27Inlet Filter1746.434Inlet Connector1746.435Inlet Clamp1746.437Coil1746.446Switch / LED 1746.445Cover1

Page 14 - COMMISSIONING

21ACCESSORIESGenuine Mira accessories can be purchased direct from Customers Services (our contact details can 

Page 17

24CUSTOMER SERVICE1175283-W2-B © Kohler Mira Limited, November 2011Mira is a registered trade mark of Kohler Mira Limited.

Page 18

1These instructions must be left with the userLOW HIGHECOTEMPERATUREPOWERUser Guide

Page 19 - SERVICING

2to section 'FAULT DIAGNOSIS'

Page 20 - SPARE PARTS

3IMPORTANT SAFETY INFORMATION Make sure that you fully understand how 

Page 21 - ACCESSORIES

4OPERATION“IMPORTANT SAFETY INFORMATION”Switch on the electrical LOW HIGHECOPOWERTurn power control to the 

Page 22

5

Page 23

3IMPORTANT SAFETY INFORMATIONWARNING - This shower can deliver scalding temperatures if not operated, installed or maintained in accordance with the i

Page 24 - CUSTOMER SERVICE

6USER MAINTENANCEUse your thumb or a soft cloth to wipe any limescale from the soft nozzlesThere are no user serviceable parts    

Page 25 - 

7SymptomStart/Stop Light is ON or OFFPowerControl PositionPossible Cause Possible RemedyShower fails OFF Isolator switch in the off 

Page 26

8CUSTOMER SERVICEMira is a registered trade mark of Kohler Mira Limited.

Page 27 - IMPORTANT SAFETY INFORMATION

4PACK CONTENTSDocumentationTick the appropriate boxes to familiarise yourself with the part names and to 1 x Mira

Page 28 - OPERATION

5WIRING DIAGRAMINLET CONNECTORTERMINAL BLOCKHEATER TANKMICROSWITCH (L)MICROSWITCH (R)SOLENOIDLED/LED HOUSINGPUSH BUTTON SWITCHBROWN BGREEN DBLUE CRED

Page 29

6SPECIFICATIONSEuropean Conformity InformationThe Mira Sport range of showers complies with the following European directives:2006/95/EC Low Voltage D

Page 30 - USER MAINTENANCE

7INSTALLATION REQUIREMENTSthe front of this guide, and the requirements det

Page 31

8Zone of 30 mm MinimumToilet or Bid

Page 32

9LOW HIGHECOPOWERTEMPERATUREWARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:Electrical1. The electrical installation must comply with