11
Swivel the inlet connector
assembly to suit. Remove the
inlet blanking cap. Avoid trapping
the green earth bonding wire.
Install the mains-fed cold water
supply pipe. Do not overtighten.
9
6
8
7
Thoroughly ush the mains-
fed cold water supply pipe.
The supply must be clean
and free from debris BEFORE
connecting the Mira Orbis.
To ush the pipework, turn on
the water supply and drain a
minimum of 10 litres (2 gallons) of
water into a bucket or catchment
area. Turn off the water supply.
Using the installation template
supplied,mark the positions
of the three xing holes.
Note! Ensure that there are
sufcient lengths of supply pipe
and electrical cable to reach the
connection points.
10
11
Drill and plug the top two xing
holes. Secure the shower to the
wall with appropriate screws
provided. Drill the bottom xing
hole with the product in place.
Alternative xings (not supplied)
may be necessary for some wall
structures. Avoid drilling into any
supply cable/pipe.
Caution! Do not drill into
buried cables or pipes.
Upper and lower case inserts are
supplied and should be tted.
Trim the inserts to t incoming
electrical or water supplies
before tting.