Mira Orbis User's Guide Page 27

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 26
27
Symptom LCD
Back
Light
Low Flow
Warning
Heater Setting
Low/Medium/
High
Probable Cause Probable Remedy
No change in
temperature
between Low/
Medium/High
setting.
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
Any
Any
Insufcient mains
water pressure.
Possible failure of
thermostatic valve or
heater tank.
Control PCB failure.
Thermal Trip failed.
Contact local water
company.
Check the continuity
of the heater tank
and replace parts as
necessary.
Replace Control PCB
assembly.
Replace thermal trip
or check the continuity
of the heater tank
/ replace parts as
necessary.
Water will not
turn off.
ON
ON
OFF
ON
Any
Any
Inlet valve, solenoid,
stop switch, relay PCB
or Control PCB faulty.
Supply pressure
below 20 kPa
(0.2 bar).
Replace as necessary.
Contact local water
company. Check mains
water static pressure.
Appliance fails
to produce hot
water when set
on ‘Medium /
High’ heater
setting.
ON
ON
ON
ON
OFF
OFF
Medium/High
Medium/High
Medium/High
Inlet valve assembly
faulty.
Faulty relay PCB.
Possible failure of
the thermal switch.
Heater tank failure.
Replace inlet valve
assembly.
Replace relay PCB.
Check the continuity
of the heater
tank / replace parts as
necessary.
Replace.
Unable to select
a cool enough
shower.
ON OFF High Due to the rise in
mains water supply
temperature, the
heater setting may be
too high.
Press the ‘Medium’
heater setting and
adjust the temperature
control until a suitable
temperature is
reached.
Clock does not
keep time
ON OFF Any Battery needs
replacing.
Faulty Control board.
Replace battery.
Replace.
E1 displayed on
screen
ON OFF Any Check thermistor is
plugged in.
Ret or replace.
Note! The Mira Orbis Thermostatic Shower offers a water saving feature where the shower will
automatically switch OFF after 40 minutes of continuous use.