1These instructions are to be left with the user8.5, 9.5 & 10.8kWInstallation & User GuideMIRA PLAYELECTRIC SHOWER
10Read the section “Important Safety Information” rst.Electrical Checklist1. Electrical supply fuse and consumer unit are adequate for the product.2
11Electrical (checklist in detail)1. In a domestic installation, the rating of the electricity supplier’s fuse and the consumer unit must be adequate
12INSTALLATIONMira PlayRead the section “Important Safety Information” rst.1.INSTALLATION TEMPLATELNMira SportAttention Installer2. 3.4. 5. 6.7.
1310. 11.12. 13.14. 15.Connect supply pipe. Do not overtighten!Feed cable into Case. Fit Earth sleeve (not supplied) and strip insulation
14Mira Response Adjustable Shower FittingsRead the section “Important Safety Information” rst.1. 2.3. 4.Position as shown to prevent back siphoning.D
155. 6.7. 8.9.Mark the positions of the slots on both top and bottom Supports.Caution! Do not drill into buried cables or pipes.First x bo
16COMMISSIONINGIf you are unsure how an electric shower works, please read through the section “User Instructions” before continuing.PUSHCOLD_+1. 2. 3
17_+PUSHSet control to HIGH.13. 14.15. 16.Note! A slight “hissing” sound may be heard from the appliance during operation. High mains water pressure a
18How Your Electric Shower WorksHot water is produced by passing cold water through a heating tank._+COLD_+_+The shower has three heater settings
19The Effect of Seasonal Changes***_+For a cold shower select Low.For a summer warm shower select Medium.For a winter warm shower select High.During e
2If you experience any difculty with the installation or operation of your new Electric Shower, please refer to ‘Fault Diagnosis’, before contacting
20PUSHPUSH_+_+Using Your ShowerRead the section “Important Safety Information” rst.1.Switch on electrical supply. Press START button.Set to desired p
21Changing the Spray SettingThe handset has three different spray settings (Start, Soothe and Force).1. 2.3.Adjusting the Clamp BracketStartTurn the S
22FAULT DIAGNOSISThe trouble shooting information table below gives details on probable causes and remedies should difculties be encountered whilst t
23SymptomPower LightHeater Setting Low/Med/HighProbable Cause Possible RemedyNo hot water from shower, with the controls in any position.ON ON
24SymptomPower LightHeater Setting Low/Med/HighProbable Cause Possible RemedyONONMed/HighMed/HighOne of the heater tank elements has failed.S w i
25SymptomPower LightHeater Setting Low/Med/HighProbable Cause Possible RemedyWater leaks from the bottom of the cas e nea r the outlet. There is
26MAINTENANCEHandset - CleaningCLEARClean with mild washing up detergent or soap solution. Wipe dry with soft cloth.Poor shower performance can be avo
27Relief Valve Assembly - ResettingRead the section “Important Safety Information” rst.ScrewsHeater TankFlow Regulator AssemblySwitch AssemblyBallBa
28DIMENSIONS225 mm 98 mm335 mm332 mm52 mm600 mm
29WIRING DIAGRAMSTART/STOPInternal Wiring Diagram
3INTRODUCTIONThank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide tho
30SPARE PARTSMira Play406.27 Inlet lter (with ‘O’ Seal tted)416.38 Inlet Clamp Bracket439.75 Inlet Connector Assembly439.76 Clamp Bracket - comp
314 mm MINIMUMImportant Note! Push-t connectors must be assembled back to back onto terminals of micro-switches.A minimum air gap of 4 mm must b
32Mira Response Shower Fittings150.58 Hose - chrome411.05 Adjuster Ring - white411.23 Clamp Bracket Assembly - white411.30 Slide Bar Support Assem
33411.05413.22632.73411.96A411.92413.58411.53411.23413.24411.94411 94411.30413.30632.73150.58411.58413.33411.91413.34411.94411.94411.30413.30
34ACCESSORIESEverclear ShowerheadWhite - 2.1616.030Chrome - 2.1616.031Mira's new Everclear range has been specially designed for hard water areas
35NOTES
36GuaranteeYour product has the benefit of our manufacturer’s guarantee which starts from the date of purchase.To activate this guarantee, please
4IMPORTANT SAFETY INFORMATIONInstallation must be carried out in accordance with these instructions, and must be conducted by designated, qualied and
52. Caution!2.1. Read all of these instructions and retain this guide for later use.2.2. The electrical installation must comply to “BS 7671 - Requ
6PACK CONTENTS CHECKLISTTick the appropriate boxes to familiarize yourself with the part names and to conrm that the parts are included. 1 x Mira Pla
7Mira Response Adjustable Shower Fittings 2 x Wall Plugs 2 x Fixing Screws 1 x Slide Bar 1 x 1.25 m Flexible Hose 2 x Slide Bar End Supports 2 x Slide
8INSTALLER INSTRUCTIONSRead the section “Important Safety Information” rst.Plumbing Checklist1. Minimum maintained inlet pressure 8.5 kW and 9.5 kW
9Plumbing (checklist in detail)1. The appliance is designed to operate with a minimum maintained inlet pressure of 70 kPa (0.7 bar), for 8
Comments to this Manuals