INSTALLATION
General
1. The installation, commissioning and maintenance must be carried out according
to instructions supplied, and must be conducted by quali ed or competent
person.
2. Before starting installation, ensure that all site requirements correspond to
information given in the SPECIFICATION section.
3. DO NOT install product in a position where it could become frozen.
4. Install in a position with easy access for maintenance.
5. Accessible isolating valves MUST be provided for maintenance.
6. The supply pipework MUST be thoroughly ushed to remove any debris before
connection.
7. The hot water supply must be connected to left inlet (next to the ow selector).
This shower does not allow for reversed inlets.
8. Installations must comply with the requirements of UK Water Regulations/Bye-
laws (Scotland), Building Regulations or any particular regulations and practices,
speci ed by the local water supplier.
9. No form of outlet ow control should be tted. Only use L11 shower ttings
recommended by the manufacturer/supplier.
10. Do not install the shower control in a position that restricts service access. A
minimum distance of 150mm is required between the hot and any side wall.
11. Do not use excessive force when making connection.
12. The supplied wall mounting bracket must be used for stud partition or laminated
panel walls to ensure the valve is fully supported.