Mira Escape User's Guide Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
7
Specifications
1. Plumbing
Minimum maintained inlet pressure 70 kPa (0.7 bar).
100 kPa (1.0 bar) recommended for satisfactory operation.
Maximum static inlet pressure 1000 kPa (10 bar).
Minimum static pressure 20 kPa (0.2 bar) to keep the inlet valve closed.
2. Electrical
The Mira Escape 9.8kW requires a 45 Amp fuse.
The terminal block will accept cable up to 16 mm².
3. Standards and Approvals
The Mira Escape complies with all relevant directives for CE marking.
Installation Requirements
1. Plumbing
The appliance is designed to operate with a minimum maintained inlet pressure
of 0.7 bar up to a maximum static inlet pressure of 10 bar. When installed in
very hard water areas (above 200 ppm temporary hardness) your installer
may advise the installation of a water treatment device, to reduce the effects
of limescale formation. Your local water company will be able to advise the
hardness of water in your area.
It is recommended that a non-restrictive (free owing) isolating valve is tted in
the cold water supply pipe to allow the complete maintenance of the appliance.
Do not use a valve with a loose washer plate (jumper) as this can lead to a
build up of static pressures.
The appliance is suitable for installation within the shower area. It is tted with
a pressure relief device and must be positioned over a water catchment area
with the controls at a convenient height for all users.
The appliance must be tted on to a nished at and even wall surface (this
wall surface should be tiled or waterproofed). DO NOT t the appliance to
the wall and tile up to the case. For safety requirements, an air gap must be
left behind the appliance.
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 31 32

Comments to this Manuals

No comments