Symptom Power
Light
Low
Flow
Light
Heater
Setting
I/II/III
Probable Cause Possible Remedy
L o w o r n o
ow.
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
Any
Any
Any
Any
Any
Any
Any
Water supply pipework
or inlet filter restricted
by a blockage or partial
blockage.
I n s u f f i c i e n t w a t e r
supply pressure/ow for
operation.
Other outlets (e.g. toilet,
garden hose, washing
machine, etc.) drawing
water while the shower is
being used.
Handset blocked.
Service tunnel or cover
not tted correctly causing
Start/Stop button not to
operate.
Inlet Valve faulty.
Heater Tank excessively
scaled.
Water supply pipework
or inlet filter restricted
by a blockage or partial
blockage.
C o n t a c t l o c a l wa t e r
company. Supply pressure
must be a minimum of
0.7 bar. Note: If other
appliances are operating,
pressure may drop below
0.7 bar.
Turn off other appliances
whilst shower is in use.
Remove and clean.
Check case inserts are
cut and fitted correctly.
Check services (electrical
or plumbi n g) are not
interfering with location of
service tunnel or cover.
Replace.
Replace. In hard water
areas consider the use of
a water softener.
Operation of
te mp e r a tu re
c o n t r o l h a s
l i t t l e o r n o
effect on water
temperature.
ON
ON
ON
ON
ON
OFF
OFF
OFF
II/III
II/III
II/III
II/III
Handset or inlet filter
blocked.
Inlet valve faulty.
Heater tank failure.
Microswitch failure.
Remove and clean.
Replace.
Replace.
Replace.
No change in
te mp e r a tu re
between I/II/III
settings.
ON
ON
ON
OFF
Any
Any
Insufficient mains water
pressure.
Possible failure of flow
valve, microswitch or
heater tank.
C o n t a c t l o c a l wa t e r
company.
Check the continuity of
the microswitch or heater
tank and replace parts as
neccessary.